How to Purchase, Store & Handle Diesel Exhaust Fluid

Diesel engines in trucks and other applications sold in the United States must meet stringent U.S. Environmental Protection Agency (EPA) emissions requirements.

Photo courtesy of Picasa

5 min to read


Diesel engine vehicles can be damaged by using low-quality diesel exhaust fluid (DEF). This includes catalyst poisoning, deposits which can restrict equipment from operating, and DEF injector and filter clogging. Repairs can be very expensive with long downtime possible, and damage could void the manufacturer’s warranty. These potential dangers demonstrate why education about using high quality DEF is crucial.

Diesel engines in trucks and other applications sold in the United States must meet stringent U.S. Environmental Protection Agency (EPA) emissions requirements. Many of those engines use selective catalytic reduction (SCR) to meet the requirements. SCR is an emissions aftertreatment technology that converts nitrogen oxides (NOx) in the diesel-engine exhaust stream into nitrogen and water vapor, two natural components in the air we breathe.

Ad Loading...

Diesel exhaust fluid (DEF) is an essential part of the process. It is injected into the diesel exhaust stream, and the heat from the exhaust, the fluid, and a catalyst convert the NOx into the harmless gases.

DEF is made from a 32.5% solution of technically pure urea with the rest of the mixture consisting of purified water. For the SCR unit to operate properly, the DEF must meet an exacting purity standard established by the International Organization for Standardization (ISO). This ensures that the DEF provides the purity required by diesel engine manufacturers and the quality to preserve the emissions control system and the environment.

Purchasing DEF on the Road

On the road, one of the main challenges for drivers is knowing the brand of DEF they are being sold as many fill up locations don’t identify the manufacturer and brand name on the receipts to their customers. Regulations in many states require this information be provided when bulk DEF is delivered to the location.

Without it, fill up locations cannot provide the information on dispenser receipts. It is then difficult for drivers to confirm they are buying DEF that is licensed by API’s Diesel Exhaust Fluid Certification Program unless it is marked, or the information is otherwise conveyed.

Many diesel engine manufacturers recommend that drivers use API-licensed DEF.

Ad Loading...

Drivers accustomed to purchasing DEF in containers should look at the expiration date on the bottle and be sure to use it before this date as the product has a limited shelf life. If a date is not present, ask for the most recently delivered DEF products.

Storage conditions also have an impact on its quality. DEF can be expected to have a minimum shelf life of 12 months or even longer in optimal conditions. Check the label for recommended storage temperatures. API recommends that you don’t store it for too long in your truck once you purchase it, especially if the storage area in the vehicle is routinely hotter than the recommended storage temperatures displayed on the label.  Be sure to look for the API certification mark on the bottle as well.

Purchasing DEF for Shop Use

API has found that the biggest misconception by fleet managers is the belief that if the urea concentration of their DEF is on spec, then the DEF meets the required quality. While it is absolutely true that the concentration is very important, there are many other important quality characteristics built into the ISO 22241 specification.

DEF is composed of 32.5% technically-pure urea in pure water.  Each of these components are critical to the manufacture of DEF that meets the quality standard. Use of substandard urea (such as agricultural-grade urea commonly used as fertilizer) or use of water derived directly from the public water system without proper treatment can introduce contaminants and metals that are not only detrimental to the life of the Selective Catalytic Reduction (SCR) system but can also affect the SCR system’s ability to reduce harmful NOx emissions.

Fleet managers responsible for procuring DEF should confirm that their suppliers are providing DEF that meets the ISO quality standard. One way to do this is to ensure that their supplier is providing a Certificate of Analysis with every shipment that addresses all of the quality characteristics that the specification requires. Fleets and drivers can check to see if the DEF they are buying is licensed through API’s real-time directory of licensees on the API website.

Ad Loading...

Make sure any diesel exhaust fluid you purchase is certified by the American Petroleum Institute by looking for this logo. 

Image courtesy of American Petroleum Institute 

Managing DEF in Shops

For shops, the handling, storage and dispensing of DEF is very important so that off-spec DEF doesn’t reach the marketplace. Temperature during transport or at the point of storage or sale can harm the shelf life of DEF sold in containers. Make sure the stock is rotated to use the oldest product first. Proper storage temperatures in a shop is also vital. Storing in temperatures above 86 degrees Fahrenheit will limit the shelf life of the DEF over time. Some additional things to consider in storing and handing DEF include the following:

  • Bulk storage tanks should be dedicated for DEF. Don’t switch products in the bulk tank without thoroughly rinsing the tank with distilled or de-ionized water or on-spec DEF.

  • A closed loop system for transferring DEF from a drum or bulk tank is recommended, so contaminants don’t get into the DEF. This is particularly important in a shop or construction site that has dust or dirt in the air.

  • Use dedicated equipment for dispensing DEF. Don’t use funnels, pitchers, hoses, etc. that are used for other fluids when putting DEF in a tank.

  • Anything used for dispensing DEF should be cleaned with distilled or de-ionized water and followed by a DEF rinse. Don’t use tap water for cleaning.

For shops and drivers, it’s important to know what you are putting into your DEF tank. The quality of the DEF going into your vehicle is as important as the quality of the engine oils or fuels used in your vehicles. Use of API-licensed Diesel Exhaust Fluid will ensure that the DEF meets the high standards required by engine and vehicle manufacturers.

About the Author: Jeffrey Harmening is the team lead, diesel exhaust fluid, for the American Petroleum Institute.

Subscribe to Our Newsletter

More Fuel

Promotional graphic for Work Truck’s “Trucks, Tips & Tours” explaining hydrogen fuel production, featuring wind turbines, solar panels, a hydrogen storage tank labeled “Hydrogen H2,” and text showing water and electricity converted into hydrogen fuel.
Fuelby Wayne ParhamMay 27, 2026

How Hydrogen Fuel Is Produced for Fuel Cell Trucks

How is hydrogen produced for fuel cell trucks? Let’s learn more about that as Pajarito Powder CEO Christian Mohrdieck walks us through the process in this video.

Read More →
Graphic promoting the RoadFlex mobile app for fleet fuel risk management. Three smartphone screens display dashboard navigation, fuel station mapping, and transaction tracking over a highway background with the RoadFlex logo below.
FuelMay 26, 2026

RoadFlex Launches Mobile App for Drivers and Fleet Managers

RoadFlex has launched its mobile app to give fleet teams a faster, easier way to manage fleet card activity, capture receipts, review transactions, and maintain spend visibility from the field.

Read More →
Screenshot of the OptiMile.Pro platform displaying a fuel price heat map across the United States. The interface shows station pricing data, color-coded map markers, and dashboard metrics alongside the OptiMile.Pro logo.
FuelMay 20, 2026

OptiMile Pro Launches Fuel Planning Platform to Cut Fleet Fuel Spend

OmtiMile Pro’s new software replaces the "fill up when empty" habit with a globally optimized fuel plan that picks the cheapest stop in the fleet's contracted network and the precise amount of fuel to load on every run.

Read More →
Ad Loading...
Infographic titled “Average Diesel Fuel Prices: May 2026” featuring a fuel nozzle, a line chart of rising on-highway diesel prices, and a regional bar chart showing price changes across U.S. regions with directional arrows.
Fuelby Wayne ParhamMay 19, 2026

May Diesel Trends Update

The average price of a gallon of diesel decreased by more than 4 cents this week, and four of the five regions saw similar price improvements.

Read More →
Fuelby Wayne ParhamApril 28, 2026

April Diesel Trends Update

The national average price of a gallon of diesel dropped by more than 5 cents this week, and all but one region reported price decreases.

Read More →
Map of Southern California, surrounded by orange background on left and right, and an inset logo for ChargePoint.
Fuelby News/Media ReleaseApril 20, 2026

ChargePoint & South Coast Air Quality Management District Surpass 90 EV Charger Installations Across Southern California

ChargePoint has enabled more than 90 charging ports for the South Coast Air Quality Management District in Southern California. The project replaced outdated chargers with 55 new, Level 2 ChargePoint units capable of serving 94 vehicles simultaneously.

Read More →
Ad Loading...
Man in business attire against a blue background with logo for Work Truck and headlines Leadership Update and Pajarito Powder.
Fuelby News/Media ReleaseApril 17, 2026

Pajarito Powder Appoints Hydrogen Industry Veteran as New CEO

Pajarito Powder has appointed Christian Mohrdieck, who has a wealth of experience and knowledge in both the fuel cell and electrolyzer businesses, as its new CEO.

Read More →
Chart shows increases or decreases of diesel fuel price in the US and five regions.
Fuelby Wayne ParhamMarch 24, 2026

March Diesel Trends Update

The average price of diesel remains above $5 per gallon in every U.S. region and nationally. With continued oil supply chain challenges in the Middle East, prices are significantly higher than a year ago and also two years ago.

Read More →
SponsoredMarch 1, 2026

Report: How AI Is Reshaping Fleet and Field Service Operations

AI is moving beyond the back office and into the driver’s seat of work truck and field service operations. New research shows fleets are using AI to improve predictive maintenance, optimize dispatch and routing, reduce downtime, and boost technician productivity, while also tackling challenges around workforce adoption and data readiness. Discover the trends, technologies, and real-world use cases shaping the future of connected work truck fleets.

Read More →
Ad Loading...
Stacked suitcases with a WEX logo at an airport window, illustrating WEX and Engine connecting fuel and travel payments for fleet lodging, rental cars, and airfare.
Fuelby Lauren FletcherFebruary 27, 2026

WEX Expands Payment Platform to Include Discounted Travel Through Engine Partnership

For commercial fleets and trucking operations, the change is designed to address a common pain point: travel expenses that fall outside traditional fuel controls.

Read More →