6 Considerations for Switching to Electric Standby
If you’re considering converting your company’s fleet and facilities over to electric standby, conversion to electric transport refrigeration units (a.k.a. eTRUs) is an investment in your company’s employees, equipment, and bottom line.

Fuel costs are important to review when considering converting to electric standby. The average TRU will burn 0.8 gallons of diesel per hour, whereas an eTRU only uses 8.1 kilowatts of electricity per hour.
Photo: SafeConnect
If you’re considering converting your company’s fleet and facilities over to electric standby, conversion to electric transport refrigeration units (a.k.a. eTRUs) is an investment in your company’s employees, equipment, and bottom line. In addition to the financial benefits, you’ll also be reducing your environmental impact and getting ahead of pending legislation that could make electric standby necessary.
But, as with any investment, it’s important to do research and fully understand the costs and savings of the transition, as well as to accurately predict how long it will take to get a return-on-investment (ROI).
Consider these six important - but often overlooked - components of electric standby to make sure you are ready, and your conversion is efficient and effective (with no unwanted surprises).
6 Components of an Electric Standby
Electrical Capacity: The first question to ask yourself is, “do we have enough electrical capacity to convert?” Converting to electric standby can significantly reduce fuel costs but will increase your electricity consumption. This will not impact your ROI (see the “fuel costs” section below) but it’s important to understand whether the current onsite electrical capacity can handle the additional load.
If that’s not the case, utility companies are often willing to provide funding to help defray or completely cover the cost of additional infrastructure or transformers needed to handle the conversion. In any case, be sure to let your utility company know you are making the switch to ensure you’ll have the extra capacity you need available during the time of day you’ll need it.Infrastructure: Something that many organizations overlook are the facility upgrades needed for electric standby conversion (e.g., access to 3-phase power at dock doors, trailer staging areas, etc.). Be sure to contact an electrician to understand any costs that would be associated with getting power to the necessary locations. There are different docking station configurations available for dock door or pedestal stations. Research the options and plan for the configuration that is best for your facility and daily company operations.

There are both four-pin and six-pin plug configurations as well as tension release mechanisms available on the market. When considering equipment expenses, it’s also important to consider the lost opportunity cost of NOT plugging in your trailers.
Photo: SafeConnect
Fuel Costs: Fuel costs are important to review when considering converting to electric standby. The average TRU will burn 0.8 gallons of diesel per hour, whereas an eTRU only uses 8.1 kilowatts of electricity per hour. Electricity prices are historically lower than diesel and have also proven to be less volatile. Consistent pricing makes planning and budgeting for expenses easier and more predictable. Idling TRU diesel engines have considerably higher costs than running eTRU electric motors.
Research shows that most companies significantly underestimate the amount of TRU diesel idling that occurs while on standby at their facilities. Want to get a more detailed understanding of the potential savings? Use this electric standby Savings Calculator.Maintenance Costs: In addition to fuel costs, TRU idling while at the facility is a significant contributor to maintenance costs. TRU maintenance contracts are typically based on total diesel engine run time. Because electric motors are virtually maintenance free, the e-motor’s run time is not a component in the maintenance cost equation. The e-motor’s run time displaces the diesel engine run time.
Equipment Costs and Safety – How You Plug in Matters: Equipment costs for eTRUs may seem like a pretty straightforward line item to calculate, but it can be easy to overlook items such as plugs and wiring on trucks or trailers, labor to modify trailers, the placement of barriers to protect equipment, and replacement of scarred or damaged plugs due to human error.
A major consideration is addressing the potential danger resulting from an accidental drive-off, which could expose live high-voltage wires and create the need for expensive repairs. There are both four-pin and six-pin plug configurations as well as tension release mechanisms available on the market. When considering equipment expenses, it’s also important to consider the lost opportunity cost of NOT plugging in your trailers.
Things like higher fuel costs, additional maintenance costs from longer run times on the diesel engine, non-compliance with potential future regulations, and increased carbon footprint. For these reasons, it is critical to evaluate how you plug in and what type of plug and system design you use. The potential danger and upfront expenses often help to justify the initial equipment cost.

Equipment costs for eTRUs may seem like a pretty straightforward line item to calculate, but it can be easy to overlook items such as plugs and wiring on trucks or trailers, labor to modify trailers, the placement of barriers to protect equipment, and replacement of scarred or damaged plugs due to human error.
Photo: SafeConnect
Capital Investment: Finally, you’ll need to consider whether you have the capital available to complete the project. You may find that it makes sense to spread out the investment over several years. You may also be able to supplement available funds with grants and incentives from local, state and federal agencies. The Environmental Protection Agency (EPA) has developed a list of SmartWay verified technologies that improve efficiencies and help reduce the environmental impact of the trucking industry. Products with the SmartWay designation have undergone rigorous testing and evaluation processes to earn the designation.
Applications for certain grants such as those funded by the Diesel Emissions Reductions Act (DERA) may require the adoption of EPA SmartWay verified or CARB compliant technologies in order to be eligible for funding. In addition to federal, state, and local funding, many utility companies offer incentive programs to help defray the initial costs of setting up an electric standby operation. To learn more, contact your local utility provider.
About the Author: Bobby Johns is the VP of business development at SafeConnect. For more information, he can be reached via e-mail at bobby.johns@safeconnectsystems.com.
More Operations

Shades of Fleet Call for Voices: Next Up in Fleet
Apprentices, interns, young professionals, and rising leaders: share your voice in our "Next Up in Fleet" episode of our Shades of Fleet video series!
Read More →
Fleet Leadership, Skilled Trades, and Better Data Take Center Stage | Weekly Cheat Sheet
Skilled trades, fleet leadership, DataQs, and driver input take center stage in this week's Truck Chat Weekly Cheat Sheet. Watch the latest fleet headlines.
Read More →
NAFA Names 2026 Class of Fellows, Honoring Leaders in Fleet Management
NAFA Fleet Management Association (NAFA) has recognized five fleet professionals by naming them to the 2026 Class of NAFA Fellows. Find out who they are and learn more about their impact on the fleet management profession.
Read More →
Verisk CargoNet Assists in Manhattan Cargo Theft Indictment Targeting Multi-State Impersonation Ring
Verisk CargoNet assisted law enforcement efforts tied to an indictment related to an organized, multi-state cargo theft operation that allegedly took nearly $5 million in stolen goods through impersonation tactics.
Read More →
What Does a Potato Have to Do with Leadership?
From simple process improvements and creative problem-solving to the little moments that strengthen team culture, this conversation dives into the power of unexpected ideas and why innovation doesn't always arrive wrapped in new technology or a major initiative.
Read More →
Looking for a New Podcast for the Road? Start Here!
Looking for a new podcast? Truck Chat delivers fleet leadership insights, industry deep dives, AI discussions, innovations, and real-world stories.
Read More →
WTX Fleet Manager Applications Close Soon (and Yes, You Want In)
WTX Fleet Manager Applications close soon for the hosted Work Truck Exchange, Sept. 23-25, 2026, in Scottsdale, Arizona. Limited spots available, apply today!
Read More →Did You Know What You Don't See May Be Costing You Big?
As more employees choose personal vehicles (including hybrids and EVs) for business use, companies face new challenges around visibility, insurance, liability, and cost control.
Read More →
Veteran Voices in Fleet | How Military Service Shapes Fleet Leaders
Across every perspective, one message is clear: the experiences gained through military service continue to influence how veterans contribute to the fleet industry every day.
Read More →
The Fleet Lessons That Don’t Show Up on a Spreadsheet
From index cards to predictive maintenance, Robert Martinez shares the hard-earned leadership lessons that shaped nearly 40 years in fleet.
Read More →

